Raptor Set Z-Offset
Raptor 2.0 adopts 36 point bi-linear mesh bed leveling, much more precise than ordinary auto bed leveling. Before leveling, you need to set the Z offset according to below steps first:
Choose “Motion” -> “Auto home”.
Now you can see the Z axis coordinate, please remember that value as Z1.
Then choose “Motion” -> “Move axis” -> “Move Z” -> “Move 0.1mm”.
Put an A4 paper between nozzle and bed, rotate knob anticlockwise to move down Z axis until it can pass through ONLY one paper.
Then you can see the current Z axis coordinate, remember that value as Z2.
Finally calculate the Z offset by below formula:
Z offset = -(Z1-5-Z2) 5 is a safety value for Z axis lift up
So here Z offset should be -(6.5-5-0.1)=-1.4
Then choose “Configuration” -> “Advanced Settings” -> “Probe Z Offset”, set the Z offset as the value you calculated by above formula.
And save the Z offset by choose “Configuration” -> “Store settings”.
If it’s saved successfully, you’ll hear a beep sound.
then choose “Motion” -> “Auto home” again to keep safe distance between nozzle and bed.